A cloudGPS device connects to the generator controller and sends the portal what the panel sees: state and mode, alarms, voltage and current per phase, kWh, engine speed, oil pressure, temperature, battery voltage, engine hours and fuel.
Controller data, power per phase, fuel and period totals in one card.
A device at the controller, data in the portal, calculations on the server.
A compact cloudGPS device goes into the generator cabinet and connects to the controller with one cable. It is powered from the generator battery.
The device reads data the same way the manufacturer's service software does and changes nothing in the controller. Generator settings and protections stay as they were.
Data goes over the site Wi-Fi or through a GPS tracker nearby over Bluetooth. Without a connection, records are stored in the device and arrive later with exact timestamps.
Controller alarms, start, stop, overload and phase loss reach the portal, app push, email, Telegram and Viber.
The device reads data from control panels of these brands. Your model is not listed? Tell us and we will add it.
| Brand | Controllers |
|---|---|
| SmartGen | HGM6100N (HGM6110N, HGM6120N), HGM9000 |
| Datakom | D-100, D-300, D-500, D-700, DKG |
| ComAp | InteliLite 4 (AMF8, AMF9, AMF20, AMF25), InteliLite 3 |
| Deep Sea Electronics | DSE6100 MKIII, DSE7300 MKII |
| Woodward | easYgen-1400, easYgen-1800, easYgen-XT |
| DEIF | AGC 150, ASC 150, AGC-4, SGC |
| Cummins | PowerCommand |
| Caterpillar | EMCP 4 |
| FG Wilson | PowerWizard |
| Kohler-SDMO | APM303, APM402, APM403, APM802 |
| Himoinsa | CEM8, CEA8, CE7 |
| Lovato Electric | RGK |
| Mebay | DC |
| LIXiSE | LXC |
| Emko | Trans |
A separate Generators section, a report and alerts.
Running, stopped or no link, Auto, Manual or Stop mode, controller model. Power and load against the rating.
Active controller alarms and warnings with the same names as on the panel screen, and an alert for each one.
Voltage, current, power, cos φ and frequency for every phase, kWh produced per run and per period.
Engine speed, oil pressure, coolant temperature, battery voltage and engine hours from the controller.
Tank level, refuels and drains, fuel per kWh and per hour, how long the fuel will last at the current load.
Every run from start to stop: time, energy, average and peak power, fuel used, levels and refuels. PDF and Excel, scheduled email delivery.
Controller alarms and warnings arrive with the name shown on the panel screen. The server also records starts, stops, overload and phase imbalance itself, and lasting states repeat at most once an hour.
Each client picks channels and recipients in the notification settings.
A direct controller connection gives the most data. A generator without a controller is connected with meters through a GPS tracker.
| What you see | Meters and fuel sensor | Direct controller connection |
|---|---|---|
| Controller state, mode and alarms | no | yes |
| Engine speed, oil pressure, temperature, battery, engine hours | no | yes |
| Voltage, current and power per phase, kWh | yes | yes |
| Run time, starts, idle | yes | yes |
| Fuel | level sensor in the tank | from the controller or a level sensor |
| Installation | a meter on each phase and a sensor in the tank | one cable to the controller |
| Which generators | any, including those without a controller | with a controller from the list above |
Generators you need to see without driving to the site.
Shops, warehouses, fuel stations, hospitals, water utilities, residential buildings: a generator with an ATS starts by itself, and the portal shows every start, controller alarms and fuel left.
Construction sites, farms, remote sites: the generator runs without the grid, so fuel, drains, refill planning and maintenance by engine hours matter most.
Alarms, engine hours and load of every generator at the client's site: the service team learns about a problem before the client calls and plans maintenance by running time.
A controller from the list above and a cloudGPS device in the generator cabinet: one cable to the controller, power from the generator battery. Nothing changes in the controller.
A generator without a controller or with an old panel is connected through a GPS tracker: a meter on each phase and a fuel level sensor in the tank. We will suggest compatible trackers and meters for your equipment.
The device works over the site Wi-Fi, and where there is no Wi-Fi, a GPS tracker nearby passes the data on over Bluetooth.
While there is no connection, records are kept in the device memory, enough for a day and a half of running or about two weeks idle, and reach the server in order as soon as the link is back. The clock is synced over the internet, so every record has an exact time.
Engine hours come from the controller, so the schedule in the maintenance module follows the real running time of the engine: oil and filter changes, reminders and work history with attachments.
Generators and vehicles go through the same fuel analyser. If you dispense fuel for generators from your own tank, the Fuel station section shows intake, dispensing and the balance.
Generators is a separate portal module: you switch it on for a client and sell it as your own service at your own price. A separate sub-user permission covers the Generators section.
Your clients see generators in the same portal under your brand as their vehicles.
SmartGen, Datakom, ComAp, Deep Sea, Woodward, DEIF, Cummins PowerCommand, Caterpillar EMCP 4, FG Wilson PowerWizard, Kohler-SDMO, Himoinsa, Lovato, Mebay, LIXiSE and Emko: models are in the table above. Tell us your controller model and we will check compatibility.
No. The device only reads data, like the manufacturer's service software, changes no settings and sends no start or stop commands. Generator protections and automation work as before.
A GPS tracker installed nearby passes the data on over Bluetooth. If there is no connection at all, the device stores the records and sends them once the link is back.
Such a generator is connected through a GPS tracker with phase meters and a fuel level sensor: run time, load, kWh, fuel and the same alerts, but without alarms and engine data.
From the generator state and the output voltage. Time above 5% of the rating counts as under load, the rest as idle. A gap of more than 10 minutes without a single record does not count as run time.
How many litres of fuel go into each kWh produced. At the same load it stays steady, so a rise is a reason to check the engine, the fuel system or the tank.
With the same fuel analyser as for vehicles: a calm level before and after confirms the event, and the minimum refuel and drain volume is set per tank.
A controller alarm arrives with the next device record. Server events are recorded as soon as the state has held for the set time, so a short voltage spike does not become an alarm. Lasting states repeat at most once an hour.
Yes. A generator is a device in the same portal: on the map, in reports and in alerts next to the vehicles, with the same sub-user permissions.
Tell us the controller brand and model, how many generators you have and their rating. You can start with one.